<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15210</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: plate didn't arrive in conveyor
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Remote support: Setting  al No_plate_conveyer will disable checking the sensor,
but the conveyer motor will still be driven, this should be a very
temporary work.  If the conveyer works and feed out plates, then it can run
like this for a day or two. This could cause plate jam ups as plate in conveyer
sensor is not checked.
</text></DescriptionText>
<DescriptionText><text>
Place plate in conveyer over sensor and check if it is detecting using "conveyer"
command.
Check sensor wiring (eco)
check that plate makes it all the way out to the fence/end stop. check for
binding on the conveyer table.
Consider air table upgrade (intended for film).
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Resume.
Call Creo Response center if problem persists.
Call Creo service if this happens often.
</text></DescriptionText>
</OperatorAction>
<Cause>
During the process command the conveyer belts are turned on after the plate
is released from the unload table. From that time a timeout of eject_timeout
is allowed for the plate to trip the plate sensor in the conveyer (if enabled)
or else this error will be reported.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/altim_cfg_eject.xml</LinkAddress><LinkTitle>NVS: altim eject</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_cal_npc.xml</LinkAddress><LinkTitle>NVS: al npc</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:57 2008 PST
</Updated>
<Links>
<Link><LinkAddress>http://techplanet.creo.com/output/computer_to_plate/platesetter_3244/content/troubleshooting/15210.htm</LinkAddress><LinkTitle>Other: Troubleshooting information</LinkTitle></Link>
</Links>
</Error>